Power Manager workflow nodes
Workflow builder nodes of the Power Manager module.
These nodes appear in the workflow builder when the Power Manager module is available.
Apply a power level to a registered consumer. Use after a comparison node to react to battery thresholds.
| Name | Description | Type | Required |
|---|
| Trigger | Fires the action; the boolean value itself is ignored. | yes/no | Yes |
| Name | Description | Type |
|---|
| SetLevelResult | The applied level result with previous and current values. | group of fields (list) |
| Field | Description | Type | Required | Allowed values | Default |
|---|
| Consumer id | Identifier of the consumer whose level should change. | text | Yes | 1 to 64 characters | |
| Level | Target power level: normal, reduced, minimal or off. | text | Yes | 2 to 16 characters | |
Emit the aggregated current battery state. Useful as a source for SoC-threshold comparisons.
| Name | Description | Type | Required |
|---|
| Trigger | Fires the action; the boolean value itself is ignored. | yes/no | Yes |
| Name | Description | Type |
|---|
| BatterySoC | Aggregated battery snapshot (percent, voltage, charging flag). | group of fields (list) |
| Field | Description | Type | Required | Allowed values | Default |
|---|
| Battery id | Restrict the read to a specific battery. Empty aggregates over all known batteries. | text | No | at most 64 characters | |
| Stale after sec | Treat the battery sample as unavailable when its last update is older than this many seconds. | number | No | 0 to 86400 | 300 |
Emit the current solar panel yield. Returns available=false when no solar sensor is configured.
| Name | Description | Type | Required |
|---|
| Trigger | Fires the action; the boolean value itself is ignored. | yes/no | Yes |
| Name | Description | Type |
|---|
| SolarYield | Solar yield snapshot (current watts, today watt-hours, availability). | group of fields (list) |
| Field | Description | Type | Required | Allowed values | Default |
|---|
| Sensor id | Restrict the read to a specific solar sensor. Empty aggregates over all configured solar sensors. | text | No | at most 64 characters | |
| Stale after sec | Treat the solar yield as unavailable when its last update is older than this many seconds. | number | No | 0 to 86400 | 300 |